Home › Industry solutions › Logistics centres: power for forklift charging, loading docks and cold stores

Logistics centres: power for forklift charging, loading docks and cold stores

Logistics sites mix very different loads: high-current forklift charging, reefer containers at the dock, sub-zero cold stores and sorting lines that cannot stop. How to specify each area, with our models.

A logistics centre has several very different electrical demands in one site: forklift charging needs high DC current, the loading dock powers reefer containers, the cold store sits below zero all year, and the sorting line must not stop. Specifying each area separately is far easier than applying one specification across the whole site.

Four typical areas

AreaKey requirementOur models
Forklift / vehicle chargingHigh current, frequent mating, no live plugging 75091 (250A 400V 5-pole IP67 high-current plug)
75131 (250A 400V 5-pole high-current panel-mounted socket)
Loading dock (reefer)Reefer 3h, which does not mate with standard 400V 6h 5946A (switched + DUO interlock)
9562 wall-mounted socket + 2175B plug
Inside the cold storeLow temperature, frost and wash-down: IP67 minimum, low-temperature seals 940027 reefer combination unit (with 3× MCB 32A)
Sorting line / workstationsSeveral circuits, impact resistant, occasionally moved 70033, 70351 (EverGUM permanent rubber combination, Type A RCD)

Two lessons

  1. Do not use ordinary sockets for forklift charging: high current and frequent mating wear the contacts quickly. Specify the high-current range and size the cable as the manufacturer requires.
  2. Always check the clock position at the dock: reefers are 3h, standard 400V 4-pole is 6h — it not going in is not a fault, it is the mistake-proofing. See choosing reefer container sockets.
Reference: the MENNEKES logistics centre solution.

Related: reefer container sockets · choosing a socket combination · choosing the current rating

For a logistics park we can specify area by area: how many forklifts, how many dock positions, the cold-store area — all in one go. Contact our engineers

Need a quote or selection advice?

Send us the model or site parameters — our engineers verify the specs and lead time, then quote.

Continue reading

How to choose industrial plugs and sockets: 5 steps to the right model
Current, poles, IP rating, mounting and brand — follow these five steps and you pick the right industrial plug or socket the first time, without trial and error.
IP44 vs IP67: what the two numbers really mean
The difference is not just a bit more water resistance. What IEC 60529 actually specifies, and how to choose for outdoor and wet areas.
Reading MENNEKES model numbers: 32xx / 27xxx / 13xA
How MENNEKES numbers its industrial plugs, sockets and connectors, and how to recognise a model at a glance.
Reading the MENNEKES 93xx series: 9322 / 9342 / 9372 / 9382 compared
93xx is the MENNEKES wall-mounted IP67 industrial socket series. The last digit gives the voltage, the third digit the poles and current. The full 9300–9382 table and the four comparisons people ask about most.
Can MENNEKES sockets be interchanged with other CEE brands? Check the clock position first
Interchangeability is not about the brand but four things: current, poles, clock position and IP rating. With the clock positions we verified against our own stock (110V = 4h, 230V single-phase = 6h, 400V 3-pole = 9h, 400V 4/5-pole = 6h, 500V = 7h).
Counting poles on industrial plugs and sockets: 3P / 4P / 5P explained
One model is written 3P on one page and "3-pole" on another — it is the same number, and the earth is always counted. With a table checked against the manufacturer datasheets (voltage and clock position included).
What people call industrial sockets: add-on = panel-mounted = flush-mounted
The same product has several names: add-on socket, panel-mounted socket and flush-mounted socket are the same thing, while wall-mounted is a different one. A full glossary so you quote the right model.
16A / 32A / 63A / 125A: how to pick the rating in three steps
The rating follows the equipment current with at least 20% headroom: 16A ≈ 7.5kW, 32A ≈ 15kW, 63A ≈ 30kW, 125A ≈ 60kW (three-phase 380V). With the conversion formulas and the four commonest mistakes.